Expanders
SPCA210.100
2-Door Expander
SPCW130.100
SiWay RF-Expander
SPCE120.100
Indication Expander
SPCE110.100
Key Switch Expander
LED indicators
4 outputs
(1 void and 1 valid per reader)
16 tri-color LEDs
2 tri-color LEDs
Special keys
4 function keys, freely
programmable
Operating voltage
9.5 ~ 14 VDC
9.5 ~ 14 VDC
9.5 ~ 14 VDC
9.5 ~ 14 VDC
Field bus
1)
X-BUS on RS-485 (307 kb/s)
X-BUS on RS-485 (307 kb/s)
X-BUS on RS-485 (307 kb/s)
X-BUS on RS-485 (307 kb/s)
Tamper contact
On-board front spring tamper
On-board front spring tamper
On-board front / back tamper
switch
On-board front / back tamper
switch
Operating temperature
-10 °C to 50 °C
-10 °C to 50 °C
-10 °C to 50 °C
-10 °C to 50 °C
Relative humidity
Max. 90 %
(non-condensing)
Max. 90 %
(non-condensing)
Max. 90 %
(non-condensing)
Max. 90 %
(non-condensing)
Color
RAL 9003
(signal white)
RAL 9003
(signal white)
RAL 9003
(signal white)
RAL 9003
(signal white)
Housing
Plastic Housing (ABS)
Plastic Housing (ABS)
Plastic Housing
(Polycarbonate)
Plastic Housing (Polycarbonate)
Dimensions
(W x H x D in mm)
200 x 153 x 47 (Housing)
150 x 82 x 20 (PCB)
200 x 153 x 47 (Housing)
150 x 82 x 20 (PCB)
112 x 92 x 28
112 x 92 x 38
Weight
0.36 kg
0.34 kg
0.19 kg
0.27 kg
Operating current
Max. 80 mA
at 12 VDC (all relays operated)
Max.60 mA at
12 VDC
Max. 70 mA at
12 VDC (all LEDs operated)
Max. 50 mA at 12 VDC (relay
and LEDs operated)
Quiescent current
Max. 45 mA at
12 VDC
Max. 60 mA at
12 VDC
Max. 30 mA at
12 VDC
Max. 30 mA at
12 VDC
Card reader
Integrated 125 kHz reader
(EM 4102)
Radio Module
Integrated SiWay RF receiver
(868 MHz)
Number of on-board
zones
4, for door release switch
(DRS) and door position switch
(DPS), or freely programmable
1
EOL resistor
Dual 4K7 (default), other
resistor combinations
configurable
Dual 4K7 (default), other
resistor combinations
configurable
Number of on-board
relays
2, for door locks or freely
programmable (single-pole
changeover, 30 VDC / max. 1
A resistive switching current)
1 (single-pole changeover, 30
VDC / max. 1 A resistive
switching current)
Programmable key
input
3 key positions (2-0-1 in 90°
steps, cylinder type
KABA1008C)
Number of card
readers
2
Card reader protocols
Wiegand 26 bit (standard),
Wiegand 36 bit (proprietary),
Clock&Data (proprietary)