AT Command Set
TC3X_ATC_01_V04.00 Page 140 of 204 29.05.2002
5.14 AT+CSDH Show SMS text mode parameters
Test command
AT+CSDH=?
Response
+CSDH: (list of supported <show>s) OK
Parameter
See write command
Read command
AT+CSDH?
Response
+CSDH:<show> OK
Parameter
See write command
Write command
AT+CSDH=
<show>
Response
TA sets whether or not detailed header information is shown in text mode result
codes.
OK
Parameter
<show> 0 do not show header values defined in commands +CSCA
and +CSMP (<sca>, <tosca>, <fo>, <vp>, <pid> and <dcs>)
nor <length>, <toda> or <tooa> in +CMT, +CMGL, +CMGR
result codes for SMS-DELIVERs and SMS-SUBMITs in text
mode; for SMS-COMMANDs in +CMGR result code, do not
show <pid>, <mn>, <da>, <toda>, <length> or <cdata>
1 show the values in result codes
Reference
GSM 07.05
Note
Vista de pagina 139