Command Interpreter (CLI)
3-6
Industrial Ethernet OSM/ESM Network Management
C79000-G8976-C137-08
Example
The following example illustrates how to use CLI commands.
Example:
The command status <E | D> [ports] is used to enable or disable OSM/ESM
ports. The user enters the following: status followed by a blank and then the
mandatory setting either E (= enable) or D (= disable) and then the optional port
numbers as described in Table 3-1. If you do not enter a port number, the
command applies to all ports.
S To enable the ports 2, 3, 4 to 6:
Enter status E 2,3,4-6 and confirm with [Return].
S To disable ports 1 and 4 to 6:
Enter status D 1,4-6 and confirm with [Return].
Note
The example refers to the 8-port variant of the OSM/ESM.
CLI Menus and Description
The following tables contain the commands, CLI menus and a brief description. If
there are several alternatives for a command parameter, the default is always the
value to the extreme left.