Siemens OSM Manual de usuario Pagina 39

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 158
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 38
Important OSM/ESM Functions
2-19
Industrial Ethernet OSM/ESM Network Management
C79000-G8976-C137-08
Extended Redundant Configuration with Network Management
The extended redundant configuration of the OSM/ESM (with the exception of the
OSM TP22 and ESM TP40) allows up to 8 rings or networks to be coupled
redundantly with two OSMs/ESMs (see also /1/)
With network management (for example in WBM), each port of the standby master
and standby slave can be configured as a standby port, see Figure 2-2. The other
ports can be used as “normal” OSM/ESM ports.
OSM ITP 62
OSM
ITP 62
ESM
ITP 80
ESM
ITP 80
1 Fiber-optic cable (FO)
2 ITP XP standard cable 9/9
OSM ITP 62
OSM ITP 62
2
2
2
1
2
2
1
Network 1
OSM ITP 53
OSM ITP 53
1
1
Network 2
Standby ports
Network 3
Standby
master
Standby
slave
Figure 2-2 Extended Redundant Configuration