Siemens CP 1515 Instrucciones de operaciones Pagina 26

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 104
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 25
Commissioning
Operating Instructions SCALANCE W 744-1PRO
26 C79000-G8976-C185-03
Remove the assembled data module from
the IDC assembly tool.
Position the top shield plate and press it
over the cable shield.
Position the lower shield place and press it
and the upper shield plate together until
they lock together with an audible "click".
Arrange the power leads and insert them as
far as they will go into the hinge elements of
the isolation body.
The following table shows the assignment
of the power leads.
Wire color code (stan-
dard)
Brown Brown Black Black
24 V 24 V Ground Ground
Power supply insert
module
1 2 3 4
Vista de pagina 25
1 2 ... 21 22 23 24 25 26 27 28 29 30 31 ... 103 104

Comentarios a estos manuales

Sin comentarios