Implementation steps
Chapter 5.
7. The Global Device Address is the address of the PLC to be polled.
Examples of Global Device Addresses are given in the tables below:
PPI-link
Syntax to use PPI
PPI,PPI node address
node address: PPI node address of the PLC
Example:
Reach by PPI the PLC with the node address 4
Table – PPI-link device address syntax
ISOTCP-link
Syntax to use ISOTCP
ISOTCP,IP address,CalledTSAP
IP address : IP address of the PLC (ex:
10.0.120.204)
Called TSAP (*) : Transport Service Access Point
For the S7-200 family, you can use the Called TSAP
4D.57 which is the default TSAP for Step7
Micro/WIN connection.
Example:
Reach by ISOTCP the PLC at IP 10.0.120.204 with
the TSAP 4D.57
Table - ISOTCP device address syntax
(*) for Called TSAP:
● If you do not use the default TSAP 4D.57 and specify your own connection in the S7-200, be
sure to:
- use the same TSAP for the Server and the Client (ex: Local TSAP:12.00, Remote
TSAP:12.00)
- Check the "Enable the Keep Alive function for this connection" feature for this connection
otherwise the eWON will not be able to poll the device after a connection lost due to the
eWON reboot.
8. Save your settings by clicking on Update Config.