05.07 DNC Plant/DNC Cell (FBDN1)
12 Auto archiving
© Siemens AG 2010 All Rights Reserved
Motion Control Information System DNC (FBDN) - 04/10 Edition
FBDN1/12-263
12.1.1 General
The auto archive function compares NC data in SINUMERIK* machines with that in
the DNC system and automatically downloads any differences to the DNC system.
On the SINUMERIK* side, DNC IFC SINUMERIK must be installed to enable the
auto archive function. The auto archive function also takes into account loaded NC
data in the SINUMERIK* NC data management system.
In addition to the main/subprograms and workpieces, all the other files on the data
management server and NC active data can be archived.
The Auto archive function downloads NC data and NC active data generated or
changed in the SINUMERIK to the DNC server automatically where it is archived.
This means that data generated or changed on the SINUMERIK (e.g. if
SINUMERIK data has been lost) is always available on the server.
Note
DNC Auto Archive is available for PCU 50/70, but not for MMC 103.
12.1.2 Auto archive ID
Archived files are assigned an auto archive identifier. The auto archive identifier
appears in the DNC list display in the Archive column (see Fig. 12-1).
The following auto archive IDs are supported:
Table 12-1: Auto archive ID
Auto archive ID Description
0 The file has not been archived or
archiving was set to 0 by the current archive run.
1 The file was the last one to be archived and is available
on the SINUMERIK. This program is the most up-to-date
version.
2 The file was archived in an earlier run, but is no longer
available on the SINUMERIK.