DNC Plant/DNC Cell (FBDN1) 05.07
10 Configuration
© Siemens AG 2010 All Rights Reserved
FBDN1/10-180 Motion Control Information System DNC (FBDN) - 04/10 Edition
End-of-line character
The end-of-line character is the character that indicates the end of a line. If the
end-of-line character is converted, the SerIntSvr proceeds as follows:
All end-of-line characters are converted to CR-LF for downloads.
All CR-LF and LF are converted according to the following table for
uploads.
Table 10-7: End-of-line character conversion during download
End-of-line character
Description
0 No conversion
1 CR CR
2 CR LF
3 LF CR
4 LF LF
5 CR CR CR
6 CR CR LF
7 CR LF CR
8 CR LF LF
9 LF CR CR
10 LF CR LF
11 LF LF CR
12 LF LF LF
13 CR
14 RD
Extract from machine configuration file:
EOBcode=0
Send baud rate
The send baud rate specifies the baud rate (differs from that for the interface
definition ([COM] section)) with which data is transmitted. If 0 is specified for
the baud rate, the baud rate of the interface description ([COM] section) is
used.
Extract from machine configuration file:
SendBaudRate =0
Send timeout
The send timeout specifies the interval in minutes after which the send job is
aborted if the machine is not ready to receive. The value 0 means that the
system will wait indefinitely.
Extract from machine configuration file:
SendTimeout=1
Send delay
The send delay specifies the interval in seconds by which the send job to the
machine is to be delayed.
Extract from machine configuration file:
SendDelay=0