05.07 DNC Plant/DNC Cell (FBDN1)
10 Configuration
© Siemens AG 2010 All Rights Reserved
Motion Control Information System DNC (FBDN) - 04/10 Edition
FBDN1/10-243
X,X2 and Y fields
The X and Y fields indicate the pixels in the top-left of the field to be displayed and
its field name.
The X2 and Y fields indicate the pixels in the top-left of the field to be displayed
without the field name.
LEN field
LEN indicates the length of the field in characters.
FIELDTYPE field
FIELDTYPE defines the field type of the screen field for the NC data Properties
screen. The following types can be defined in DNC:
Output field O
Edit field E
Combination field (combo box) COB
Checkboxes CKB
Output checkboxes OCKB
Static output field STXT
FIELDTYPE_NEW field
FIELDTYPE_NEW defines the field type for entering data (import and new NC data
screen).
This separate field type for entering data allows you to define
input fields that only appear as display fields in the standard Properties dialog, that
is, they must not be changed after data has been entered.
Output field O
Edit field E
Combination field (combo box) COB
Checkboxes CKB
Output checkboxes OCKB
Static output field STXT
SINUMERIK*: SINUMERIK 810D
SINUMERIK 840D
SINUMERIK 840Di
PCU50 under Windows with SINUMERIK 840D sl
