Siemens IK PI · 2015
AS-Interface
Masters
Masters for SIMATIC ET 200
F-CM AS-i Safety ST for SIMATIC ET 200SP
4
Overview (continued)
Supported BaseUnits
With the recommended combination of the CM AS-i Master ST
and F-CM AS-i Safety ST modules, the CM module is plugged
onto a light type C0 BaseUnit and, directly on the right of it, the
F-CM module is plugged onto a dark type C1 BaseUnit.
The AS-i cable is connected only on the light BaseUnit of the
CM module.
If the F-CM AS-i Safety ST module is not combined with the
CM AS-i Master ST module, but another AS-i master is used
instead, then the F-CM module is plugged onto a light type
C0 BaseUnit. In this case, the AS-i cable is connected on the
light BaseUnit of the F-CM module.
Note on safety:
The use of this product requires suitable protective measures
(e.g. network segmentation for IT security among others) in
order to ensure safe plant operation, see
www.siemens.com/industrialsecurity.
Configuration
The following software is required for configuration of the
F-CM AS-i Safety ST module:
STEP 7 (classic), V5.5 SP3 HF4 or higher with HSP 2093 and
Distributed Safety V5.4 SP5 or F-Configuration Pack SP11
Configuration and programming are done entirely in the
STEP 7 user interface. No additional configuration software is
needed for commissioning.
Data management – together with all other configuration data of
the SIMATIC – is realized completely in the S7 project.
The input and output channels are assigned to the process im-
age automatically and manual linking via configuration function
blocks is not necessary.
If the F-CM AS-i Safety ST module is replaced, all necessary
settings are automatically imported into the new module.
The F-CM AS-i Safety ST module occupies 16 input bytes and
8 output bytes in the I/O data of the ET 200SP station.
Application
Thanks to use of the fail-safe module in the ET 200SP, it is
possible to fulfill the safety-related application requirements in a
manner that is integrated in the overall automation solution.
The safety functions required for fail-safe operation are
integrated in the modules. Communication with the fail-safe
SIMATIC S7 CPUs is realized via PROFIsafe.
The safety application is programmed in the SIMATIC S7 F-CPU
with Distributed Safety. The fail-safe input signals of the ASI-
safe slave modules are read via the
AS-i bus line and are combined with any chosen further signals
in the fail-safe program.
The fail-safe output signals can be output through fail-safe
SIMATIC output modules or also directly via AS-i – with the aid of
fail-safe AS-i output modules, e.g. 3RK1405-1SE15-0AA2
(see page 4/10). No special functions are required for this in the
program.
Configuration examples of AS-Interface networks with CM AS-i Master ST and F-CM AS-i Safety ST for SIMATIC ET 200SP
AS-Interface configuration with SIMATIC AS-i F-Link, consisting of an ET 200SP station with CM AS-i Master ST and F-CM AS-i Safety ST modules
Safety-oriented
processing
Operational
control
Safe control
SIMATIC S7-300F
Safe position switch with door interlock
Field module
Load feeder with safe AS-i outputs
Digital K45 field module
3RA2 load feeder
Safe EMERGENCY-STOP
IC01_00288
AS-Interface / ASIsafe
PROFINET / PROFIsafe
SIMATIC
AS-i F-Link
SIMATIC
AS-i F-Link
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
1
2
AS-Interface / ASIsafeAS-Interface / ASIsafe
IKPI_04_en.book Seite 41 Montag, 6. Oktober 2014 11:32 11
© Siemens AG 2014
Vista de pagina 40
1 2 ... 36 37 38 39 40 41 42 43 44 45 46 ... 155 156

Comentarios a estos manuales

Sin comentarios