6.5 Braking resistors for MICROMASTER Vector
Electronic braking module (EBU) and braking resistors for MIDIMASTER Vector
Braking resistors for MMV
Resistor Continuous
rated
power
Peak
power
Resistance
(tol.±10%)
Peak
voltage
Dimensions Weight Drive inverter type
Order No. W
(5% on
time)
W
W
DC
V
L
mm
L1
mm
W
mm
W1
mm
W2
mm
D
mm kg
6SE3290-0CA87-2RA0
40 800 200 200 190 57 28 - 54 1.3 MMV12 - MMV75
MMV12/2 - MMV75/2
6SE3290-0CB87-2RA0
80 1600 100 450 280 271 57 28 - 54 1.7 MMV110 - MMV150
MMV110/2 - MMV150/2
6SE3290-0CC87-2RA0
200 4000 40 338 330 80 20 40 54 3.1
MMV220 - MMV300
MMV220/2 - MMV400/2
6SE3290-0DA87-2RA0
80 1600 400 280 270 57 28 - 54 1.7 MMV37/3 -MMV150/3
6SE3290-0DB87-2RA0
150 3000 200 900 280 271 83 23 40 54 2.5 MMV220/3 - MMV300/3
6SE3290-0DC87-2RA0
400 7500 85 400 390 103 28 40 52 3.8 MMV400/3 - MMV750/3
Electronic braking modules for MDV
Drive inverter
EBU Associated resistors
Type Order No.
Minimum total
resistance for
each EBU
W
Order No.
Resist-
ance
W
Brief peak rated
value (5 s)
kW
Power for
on time
=20 %
kW
Contin-
uous
rated
power
kW
Peak voltage
DC
V
MD(V)550/2 to 6SE3190-0CX87-2DA0 10 6SE3213-6SP87-0RA0 20 7.5 5 1.25 380
MDV4500/2 6SE3221-4SP87-0RA0 10 15 10 2.5 380
MD(V)750/3 to 6SE3190-0DX87-2DA0 20 6SE3214-0TP87-0RA0 40 15 10 2.5 950
MDV7500/3 6SE3222-4TP87-0RA0 20 30 20 5 950
MDV220/4 to
MD(V)3700/4
Your local Siemens sales office can provide you with information about
the range of electronic braking modules which can be supplied for these drive inverters.
Braking resistors for EBU
Resistance type Order No. Continuous rated
power
kW
Brief peak
rated value
kW
Resist-
ance
W
Notes
A 6SE3213-6SP87-0RA0 1.25 7.5 20 Only for line supply voltages
B 6SE3221-4SP87-0RA0 2.5 15 10 208 V - 240 V
D 6SE3214-0TP87-0RA0 2.5 15 40 Only for line supply voltages
E 6SE3222-4TP87-0RA0 5 30 20 380 V - 500 V
Notes:
When braking, the inverter (MMV) or the electronic braking module (option for MDV) dissipates the braking energy of the
motor and load to the externally mounted resistor. The lower the value of the external resistor, then the greater the braking
power. The resistors are able to dissipate large amounts of energy for short periods, but when used continuously, the rating is
considerably less. In order to protect the resistors against overload, the drive inverter / ‘braking chopper’ (P070), or the EBU
limits its own duty cycle (the ratio between the ON time and the OFF time) to 5% (= 12 seconds in 4 minutes! drive inverter) or
10 % (EBU). This reduces the maximum dissipation level to the values shown in Fig. 3.
If the electronic braking module is used for high load moments of inertia (or extremely short ramp-down times), it may be
necessary to connect additional resistors in parallel or connect several electronic braking modules (EBUs) in parallel. In this
case, the resistor must be adequately rated to withstand the resulting power dissipation. However, the resistance may not be
less than 40
W for 230V and 80W for 400V drive units. (more detailed information is provided in Chapter 3)