6.3. Ordering data, reactors
6.3.1 MICROMASTER & MICROMASTER Vector (1-ph 230V AC)*
Rated
power
[KW]
Designation Drive inverter
IP20/21
Order No.
line reactor 2%*
Order No.
line reactor 4%
Order No.
Output reactor**
Order No.
0.12 MM12 6SE9210-7BA40 6SE6400-3CC00-4AB0 - 6SE6400-3TC00-4AD0
0.12 MM12/2 6SE9210-7CA40 6SE6400-3CC00-4AB0 - 6SE6400-3TC00-4AD0
0.12 MMV12 6SE3210-7BA40 6SE6400-3CC00-4AB0 - 6SE6400-3TC00-4AD0
0.12 MMV12/2 6SE3210-7CA40 6SE6400-3CC00-4AB0 - 6SE6400-3TC00-4AD0
0.25 MM25 6SE9211-5BA40 6SE6400-3CC00-4AB0 - 6SE6400-3TC00-4AD0
0.25 MM25/2 6SE9211-5CA40 6SE6400-3CC00-4AB0 - 6SE6400-3TC00-4AD0
0.25 MMV25 6SE3211-5BA40 6SE6400-3CC00-4AB0 - 6SE6400-3TC00-4AD0
0.25 MMV25/2 6SE3211-5CA40 6SE6400-3CC00-4AB0 - 6SE6400-3TC00-4AD0
0.37 MM37 6SE9212-1BA40 6SE6400-3CC01-0AB0 - 6SE6400-3TC00-4AD0
0.37 MM37/2 6SE9212-1CA40 6SE6400-3CC01-0AB0 - 6SE6400-3TC00-4AD0
0.37 MMV37 6SE3212-1BA40 6SE6400-3CC01-0AB0 - 6SE6400-3TC00-4AD0
0.37 MMV37/2 6SE3212-1CA40 6SE6400-3CC01-0AB0 - 6SE6400-3TC00-4AD0
0.55 MM55 6SE9212-8BA40 6SE6400-3CC01-0AB0 - 6SE6400-3TC00-4AD0
0.55 MM55/2 6SE9212-8CA40 6SE6400-3CC01-0AB0 - 6SE6400-3TC00-4AD0
0.55 MMV55 6SE3212-8BA40 6SE6400-3CC01-0AB0 - 6SE6400-3TC00-4AD0
0.55 MMV55/2 6SE3212-8CA40 6SE6400-3CC01-0AB0 - 6SE6400-3TC00-4AD0
0.75 MM75 6SE9213-6BA40 6SE6400-3CC01-0AB0 - 6SE6400-3TC00-4AD0
0.75 MM75/2 6SE9213-6CA40 6SE6400-3CC01-0AB0 - 6SE6400-3TC00-4AD0
0.75 MMV75 6SE3213-6BA40 6SE6400-3CC01-0AB0 - 6SE6400-3TC00-4AD0
0.75 MMV75/2 6SE3213-6CA40 6SE6400-3CC01-0AB0 - 6SE6400-3TC00-4AD0
1.1 MM110 6SE9215-2BB40 6SE6400-3CC02-6BB0 - 6SE6400-3TC01-0BD0
1.1 MM110/2 6SE9215-2CB40 6SE6400-3CC02-6BB0 - 6SE6400-3TC01-0BD0
1.1 MMV110 6SE3215-2BB40 6SE6400-3CC02-6BB0 - 6SE6400-3TC01-0BD0
1.1 MMV110/2 6SE3215-2CB40 6SE6400-3CC02-6BB0 - 6SE6400-3TC01-0BD0
1.5 MM150 6SE9216-8BB40 6SE6400-3CC02-6BB0 - 6SE6400-3TC01-0BD0
1.5 MM150/2 6SE9216-8CB40 6SE6400-3CC02-6BB0 - 6SE6400-3TC01-0BD0
1.5 MMV150 6SE3216-8BB40 6SE6400-3CC02-6BB0 - 6SE6400-3TC01-0BD0
1.5 MMV150/2 6SE3216-8CB40 6SE6400-3CC02-6BB0 - 6SE6400-3TC01-0BD0
2.2 MM220 6SE9221-0BC40 4EM4704-3CB 4EM4912-2CB 6SE3200-3TC03-2CD0
2.2 MM220/2 6SE9221-0CC40 4EM4704-3CB 4EM4912-2CB 6SE3200-3TC03-2CD0
2.2 MMV220 6SE3221-0BC40 4EM4807-3CB 4EM4912-2CB 6SE3200-3TC03-2CD0
2.2 MMV220/2 6SE3221-0CC40 4EM4807-3CB 4EM4912-2CB 6SE3200-3TC03-2CD0
3.0 MM300 6SE9221-3BC40 4EM4807-8CB 4EM4912-5CB 6SE3200-3TC03-2CD0
3.0 MM300/2 6SE9221-3CC40 4EM4807-8CB 4EM4912-5CB 6SE3200-3TC03-2CD0
3.0 MMV300 6SE3221-3BC40 4EM4807-8CB 4EM4912-5CB 6SE3200-3TC03-2CD0
3.0 MMV300/2 6SE3221-3CC40 4EM4807-8CB 4EM4912-5CB 6SE3200-3TC03-2CD0
* Technical data refer to Chapter 3
6SE64... line reactors can be used for line impedances of ³ 1% and above and are comparable with 2% reactors.
The maximum line voltage when using the line reactors is 3-ph 208V - 240V +/-10% AC
** Technical data refer to Chapter 3
f
puls
<= 4 kHz When using output reactors, the pulse frequency should be reduced to 4kHz (P076).
f
max
120Hz The maximum output frequency (f
max
~ 120Hz) depends on the ratio between the drive inverter output voltage, the
voltage drop across the output reactor (V
K
) and the motor being used.
The drive inverter can be over-dimensioned as an alternative to using an output reactor (refer to Chapter 3)
Comentarios a estos manuales