Siemens SPCK422 Manual de usuario Pagina 12

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 15
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 11
DETECTORS IMKW6-10 IGBW6-10 IWFW6-10
Characteristics EOL resistor: 8.2 k
External input
Coverage area for standard window
glass : 6 m radius
Coverage area for armor coated
window glass: 3 m radius
Sensitivity settings: high / low
Sensor cable up to 2 m
Frequency
Radio protocol
868.35 MHz
SiWay
868.35 MHz
SiWay
868.35 MHz
SiWay
Event Transmission Alarm, Tamper, Test, Supervision,
Low Battery
Alarm, Tamper, Supervision,
Low Battery
Alarm, Tamper, Supervision,
Low Battery
Test mode / activation Alarm transmission test by tamper
contact or glass break simulator (GT2)
Short the water detection contacts
Power consumption Standby: ca 5 uA
Transmission: 16 mA
Standby: < 15 uA
Max: < 35 mA
Standby: < 8 uA
Max: < 26 mA
Battery Lithium 3.6 V, Type: XL-050F,
Size: 1/2AA
Lithium 3 V, Type: xx123,
Size: 2/3AA
Lithium 3.6 V type: XL-050F,
Size: 1/2 AA
EMI rejection up to 2 GHz > 10 V/m > 10 V/m > 10 V/m
Environment conditions
- Operating temperature
- Storage temperature
- Air humidity (EN60721)
- Housing protection
-10 to +50 °C
-20 to +60 °C
< 85 % r.h., non condensing
IP41
-10 to +50 °C
-20 to +60 °C
< 85 % r.h., non condensing
IP41
-10 to +50 °C
-20 to +60 °C
< 95 % r.h., non condensing
IP41
Housing Material ABS – V0 ABS – V0 ABS – V0
Dimensions
Vista de pagina 11
1 2 ... 7 8 9 10 11 12 13 14 15

Comentarios a estos manuales

Sin comentarios