MOTION DETECTORS ADM-I12W1 IR65W6-10
Coverage area Wide angle: 6 – 18 m (12 m default)
Curtain: Up to 20 m
360°, 20 m Ø (310 m
2
) at 3.6 m height
Settings Sensitivity: harsh / quiet environment by switch,
10'000 lux white light filter (optional)
Pet immunity: < 12 kg or < 30 kg
Sensitivity: standard / low (selectable by jumper)
Frequency
Radio protocol
868.35 MHz
SiWay
868.35 MHz
SiWay
Event Transmission Alarm, Tamper, Test, Supervision, Low Battery Alarm, Tamper, Test, Supervision, Low Battery
Test mode / activation Walk test & Alarm transmission test by tamper or external
magnet activation
Walk test & alarm transmission test by external magnet
activation
Walk test auto reset 1 minute after activation 2 – 3 minutes after activation
Inhibition time Approx. 2 minutes Approx. 2 minutes
Power management Automatic power saver Automatic power saver
Power consumption Standby: 8 – 12 uA
Max. 15 mA
Standby: < 12 uA
Max. < 35 mA
Battery Lithium 3 V, Type: xx123, Size: 2/3 AA Lithium 3 V, Type: xx123, Size: 2/3 AA
EMI rejection up to 2 GHz > 10 V/m > 10 V/m
Environment conditions
- Operating temperature
- Storage temperature
- Air humidity (EN60721)
- Housing protection
-10 to +50 °C
-20 to +60 °C
< 85 % r.h., non condensing
IP41
-10 to +50 °C
-20 to +60 °C
< 85 % r.h., non condensing
IP41
Housing Material ABS – V0 ABS – V0
Security grade
Environmental class
(EN 50131-5-3, EN 50131-2-2)
Grade 2
Class II
Detection pattern
Wide angle lens (standard)
Curtain lens (optional)
Dimensions