Siemens TC35 Terminal Especificaciones Pagina 269

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 439
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 268
TC35i AT Command Set
10.24 AT+FRS
s
m
obil
e
TC35i_ATC_V02.07 Page 269 of 439 1/30/04
Confidential / Released
10.24 AT+FRS Receive Silence
Syntax
Command Description
<time>=n causes the TA to report an OK result code to the TE after <time> 10 millisecond intervals of silence
have been detected on the line. This command is aborted if any character is received by the DTE. The modem
discards the aborting character and issues an OK result code. An ERROR response code results if this command
is issued while the mode is on-hook
Parameter Description
no. of 10 millisecond intervals
0...255
Note
Used for Fax Class 1 only
Write Command
AT+FRS=<time>
Response(s)
OK
If error related to ME functionality
ERROR
PIN ASC0 MUX1 MUX2 MUX3
! % % ! !
Reference(s)
TIA/EIA-578
<time>
(num)
Vista de pagina 268