HOST COMMAND SET REFERENCE
UNILINK HOST
ADAPTER5–33
USER MANUAL
5.4.7
Enable/Disable Macr
o Execution — 16
The ENABLE/DISABLE MACRO EXECUTION command processes a list of
macro buffer numbers to either enable or disable the specific macros for
execution. The exception flag is cleared for each valid macro buffer number
regardless of whether the macro is being enabled or disabled. If the macro is
successfully
enabled,
the MRSW is reset or if the macro is successfully disabled,
the
MRSW is set to the disabled T
ermination Code.
NOTE
The send Primitive and disconnect macro types can
only be enabled when their associated secondary
device is not in the secondary log.
Command: 16
ss [bb tt]
Response:
16 ss [bb rr]
Usage: OPERATION
Modes:
MHIU, HIU
Parameters:
ss
The Source Id number
.
bb The macro buffer number. The response returns the buffer
numbers
in the same order as specified in the command.
tt
01 hex to enable the macro or 00 hex to disable it.
rr The
response code for that macro buffer. The possible values are:
00
= the macro was successfully enabled or disabled as requested.
01
= the macro buffer number requested has not been allocated.
Use
the ALLOCA
TE MACRO STORAGE
BUFFERS command to
allocate
the buffer
, then reissue this request.
02
= the macro buffer number specified has a different Source Id
than the one specified. Check your macro definitions table and
reissue
with the correct Source Id.
03
= the macro buffer
specified is the action macro in a link macro
pair
which cannot be explicitly enabled or disabled.
04
= the ‘tt’ parameter specified was a value other than
00 hex or
01 hex.