HOST COMMAND SET REFERENCE
UNILINK HOST
ADAPTER5–25
USER MANUAL
5.4.4 Allocate
Macr
o Storage Buf
fers — 13
The
ALLOCATE MACRO STORAGE BUFFERS command allocates buffers for
macro storage. This command can be repeatedly issued, and the HIU will
continue to add buffers until the HIU memory is either used or a total of 254
macro
buffers have been allocated. Figure 5–6 shows the relationship between
Source Id numbers and macro buffers. These buffers remain allocated to the
Source
Id
number until an ALLOCA
TE SOURCE ID command is issued to free
them
up.
Source
ID #1
(OE)
Source ID #2
(1A)
Source ID #32
(E5)
Macro Buf
fer
#1
Macro Buf
fer
#35
Macro Buf
fer
#63
Macro Buf
fer
#87
Macro Buf
fer
#2
Macro Buf
fer
#3
Macro Buf
fer
#80
Macro Buf
fer
#97
Macro Buf
fer
#109
Macro Buf
fer
#4
Macro Buf
fer
#33
Macro Buf
fer
#60
Up
to 32
unique
source
IDs
Up
to 254
Macro
Buffers
Figure 5–6 Source Id/Macro Buffer Relationship
Command: 13
ss [xxxx rrrr]
Response:
13 ss ([bb])
Usage: OPERATION
Modes:
MHIU, HIU
Parameters:
ss The
Source Id number previously defined with the ALLOCA
TE
SOURCE
ID command.
xxxx
The length of the macro command buffer in bytes.
rrrr
The length of the macro response buffer in bytes.
NOTE
Vista de pagina 109
1 2 ... 105 106 107 108 109 110 111 112 113 114 115 ... 207 208

Comentarios a estos manuales

Sin comentarios