4 Communication settings and guide of HMI connecting with controller
Communication Setting
Supported Device
Device Bit Address Word Address Format Notes
Start/Stop STW0~3
------ D
STW0 open, start.
STW0 close, stop.
STW1 close, positive rotation.
STW1 open, negative rotation.
STW2 REV inching turning.
STW3 FWD inching turning.
Set frequency
------ HSW 0 D
Basic Function Block
------ B 0~41 DD
B16 acceleration time.
B17 deceleration time.
Deviation alarm
------ E 0~41 DD
Programmable control
function array
------ P 0~37 DD
High function array
------ H 0~38 DD
D array
------ D 0~6 D
D0: output power.
D2: running current.
Cable Diagram
Controller terminal
RJ12(male)
HMI terminal
9pin D-SUB female\male
6RX+
1RX-
4 485+
3 485-
- 39 -