6/15
Siemens IK PI · 2015
■
Function (continued)
Industrial Wireless Communication
IWLAN – Access Points IEEE 802.11n
Overview
iFeatures (only in conjunction with KEY-PLUG)
iPCF (industrial Point Coordination Function):
The iPCF mode is a good choice for applications with require-
ments for real-time and predictable response times (determinis-
tic response), even when mobile nodes are roaming from one
access point to the next. This ensures that wireless PROFINET
IO is supported and that safety-related signals, e.g. emergency
stop, can be linked into the RF field. This means that even video
signals from mobile nodes can be transmitted with a high level
of quality. The iPCF mechanism expands the IEEE 802.11
standard and must be available on both the client module
and the access point. In an RF field in which iPCF is used, no
IEEE 802.11-compliant nodes can be operated.
iPCF is recommended for applications where wireless network
nodes move along predefined paths (e.g. suspended monorail).
RCoax radiating cables or directional antennas must be used for
this purpose.
iPCF-MC (iPCF Management Channel)
1)
:
iPCF-MC is available as a further development of iPCF.
This mode should be used if IWLAN stations that also support
iPCF-MC move freely about in the coverage area (especially
when using omni-directional antennas) and are to exchange
data deterministically. This functionality can only be achieved in
connection with access points with two wireless interfaces and
the KEY PLUG.
iREF (industrial Range Extension Function):
The range of an individual access point is very important, e.g. for
path-based applications. Using iREF, it is now possible to align
the various antennas of a wireless interface in different direc-
tions. This allows a longer path or a greater area to be covered
using a single access point, which reduces the number of
channels used and the number of access points.
Note:
These iFeatures cannot be used in parallel.
Diagnostics and management
• Web-based (HTTP/HTTPS) management tool for configuration
and diagnostics using a standard browser
• LEDs for signaling operating status and fault/error states
• Signaling of faults by means of SNMP trap or e-mail to a
network management tool
• Configuration and diagnostics using Web based
Management, Command Line Interface, and SNMP. Devices
and networks can be configured using STEP 7 (TIA Portal). For
cyclic monitoring, diagnostics and documentation (reporting)
in network mode, the SINEMA Server software is recom-
mended.
1)
Available soon
Linking in an automated guided vehicle system using iPCF with the SCALANCE W774-1 RJ45 and KEY-PLUG
RCoax Cable Segment 1 RCoax Cable Segment 2
Access Point
SCALANCE
W784-1RR in
the cabinet
Access Point
SCALANCE
W784-1RR in
the cabinet
G_IK10_XX_30172
IWLAN RCoax Cable IWLAN RCoax Cable
Client Module
SCALANCE
W722-1 RJ45
Panel PC
Client Module
SCALANCE
W722-1 RJ45
Panel PC
Client Module
SCALANCE
W722-1 RJ45
Panel PC
WinAC WinACWinAC
Kap_06_IWC_en.book Seite 15 Dienstag, 7. Oktober 2014 1:47 13
© Siemens AG 2014
Comentarios a estos manuales