
6/141
Siemens IK PI · 2015
■
Technical specifications (continued)
Industrial Wireless Communication
IWLAN – Accessories
IWLAN cabling technology
Product properties, functions,
components general
Product feature
• halogen-free Yes Yes Yes Yes
• silicon-free
Yes Yes Yes Yes
Standards, specifications,
approvals
Verification of suitability
• UL-registration - - - -
• RoHS conformity
Yes Yes Yes Yes
Article No. 6XV1875-5CE30 6XV1875-5CH10 6XV1875-5CH20 6XV1875-5CH50 6XV1875-5CN10
Product-type designation IWLAN RCoax/
Antenna Connection
Cable N-Connect
RSMA Male/Male
IWLAN RCoax/
Antenna Connection
Cable N-Connect/
RSMA Male/ Male
IWLAN RCoax/
Antenna Connection
Cable N-Connect/
RSMA Male/ Male
IWLAN RCoax/
Antenna Connection
Cable N-Connect/
RSMA Male/ Male
IWLAN RCoax/
Antenna Connection
Cable N-Connect/
RSMA Male/ Male
Acceptability for application
Flexible connecting
cable for connecting
an antenna or RCoax
cable to an access
point/client
Flexible connecting
cable for connecting
an antenna or RCoax
cable to an access
point/client
Flexible connecting
cable for connecting
an antenna or RCoax
cable to an access
point/client
Flexible connecting
cable for connecting
an antenna or RCoax
cable to an access
point/client
Flexible connecting
cable for connecting
an antenna or RCoax
cable to an access
point/client
Cable length
0.3 m 1m 2m 5m 10 m
Electrical data
Number of electrical connections 2 2 2 2 2
Design of the electrical connection N-Connect/RSMA
male/male
N-Connect/RSMA
male/male
N-Connect/RSMA
male/male
N-Connect/RSMA
male/male
N-Connect/RSMA
male/male
Transmission frequency
0…6GHz 0…6GHz 0…6GHz 0…6GHz 0…6GHz
Attenuation per length
• at 2.4 GHz typical 0.53 dB/m 0.53 dB/m 0.53 dB/m 0.53 dB/m 0.53 dB/m
• at 5.2 GHz typical
0.83 dB/m 0.83 dB/m 0.83 dB/m 0.83 dB/m 0.83 dB/m
• at 5.85 GHz typical
0.89 dB/m 0.89 dB/m 0.89 dB/m 0.89 dB/m 0.89 dB/m
Return loss minimum
23 dB 23 dB 23 dB 23 dB 23 dB
Impedance Nominal value
50 50 50 50 50
Capacity per length at 1 kHz
82 pF/m 82 pF/m 82 pF/m 82 pF/m 82 pF/m
Relative speed
82 % 82 % 82 % 82 % 82 %
Mechanical data
Design of shield Braided shield made
of tin-plated copper
wires
Braided shield made
of tin-plated copper
wires
Braided shield made
of tin-plated copper
wires
Braided shield made
of tin-plated copper
wires
Braided shield made
of tin-plated copper
wires
Outer diameter
• of the inner conductor 1.4 mm 1.4 mm 1.4 mm 1.4 mm 1.4 mm
•of dielectric
3.8 mm 3.8 mm 3.8 mm 3.8 mm 3.8 mm
• of the cable sheath
6.3 mm 6.3 mm 6.3 mm 6.3 mm 6.3 mm
Symmetrical tolerance of outer
diameter of cable sheath
0.2 mm 0.2 mm 0.2 mm 0.2 mm 0.2 mm
Thickness of the cable sheath
0.76 mm 0.76 mm 0.76 mm 0.76 mm 0.76 mm
Material
• of inner conductor Cu Cu Cu Cu Cu
•of dielectric
polyethylene foam polyethylene foam polyethylene foam polyethylene foam polyethylene foam
• of the cable sheath
FRNC FRNC FRNC FRNC FRNC
Color of the cable sheath Pastel turquoise Pastel turquoise Pastel turquoise Pastel turquoise Pastel turquoise
Article No. 6XV1875-5AH10 6XV1875-5AH20 6XV1875-5AH50 6XV1875-5AN10
Product-type designation IWLAN RCoax/Antenna
Connection Cable
N-Connect Male/ Male
IWLAN RCoax/Antenna
Connection Cable
N-Connect Male/ Male
IWLAN RCoax/Antenna
Connection Cable
N-Connect Male/ Male
IWLAN RCoax/Antenna
Connection Cable
N-Connect Male/ Male
Kap_06_IWC_en.book Seite 141 Dienstag, 7. Oktober 2014 1:47 13
© Siemens AG 2014
Comentarios a estos manuales