Configuration Using the Wizards of Web Based Management
Operating Instructions SCALANCE W78x
88
, the maximum key length is also 128 bits.
.5.7 Settings for the Security Level Medium in Access Point Mode
With the Auto setting
5
Authorization Lifetime text box
uthentication in seconds. The minimum time is 1
e is 12 hours (enter 43200). The default is 1
RADIUS Se
In addition to the IP address and the port, you must also specify a password
(maximum 128 characters) and confirm it in a second box. In the Maximum
Retransmissions text box, you enter the maximum number of transmission
attempts. The maximum possible value is 5, the default is 2.
Enter the period of validity of the a
minute (enter 60), the maximum tim
hour (3,600 seconds).
rver Table
You can enter the data for two RADIUS servers; the information in the Backup
column is used if the server defined in the Primary column is not available.
C79000-G8976-C184-07