Siemens CP 1515 Instrucciones de operaciones Pagina 260

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 274
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 259
Appendix
C79000-G8976-C184-07
260
snScalanceWiPCFPNI
OmaxSTAs
111
snScalanceWPNIOValue -
Description of the last
snScalanceWiPCFPNIOmaxST
As or
snScalanceWiPCFPNIOCycleTi
me trap
Is generated when there are too
many clients registered for the
specified update time in iPCF
mode with PNIO support.
snScalanceWiPCFPNI
OCycleTime
112
snScalanceWPNIOValue -
Description of the last
snScalanceWiPCFPNIOmaxST
As or
snScalanceWiPCFPNIOCycleTi
me trap
Is generated when the specified
update time in iPCF mode with
PNIO support cannot be kept to.
snScalanceWForcedR
oamingVapStateChan
ged
ceWVirtualApIndex
- Index of the VAP
snScalanceWVirtualApState
(5)
Generated when the status of
the VAP changes.
121
snScalan
- Current State of the VAP
unknown (0)
authenticated (1)
associated (2)
powersafe (3)
adhoc (4)
joined
vap-is-up (6)
vap-starting (7)
vap-is-down (8)
locked (9)
vap-connected (10)
Operating Instructions SCALANCE W78x