Mounting
5.1 Removing / fitting the housing cover
SCALANCE W786 outdoor access point
20 Operating Instructions, 06/2013, A5E02280428-08
Figure 5-1 Removing the cover
A Sealing cap
B Cover screw
C Housing cover
Follow the steps below to remove the housing cover:
1. Remove the sealing caps from the housing cover (position
A
in the figure above)
2. Loosen the screws in the cover (position
B
in the figure above).
3. Remove the housing cover (position
C
in the figure above).
Fitting the housing cover
Fitting the housing cover is carried out in the reverse order. Tightening torque for the cover
screws 1.8 Nm.