AT Command Set
MC35_ATC_01_V04.00 Page 30 of 238 02.04.2002
2.30 ATV Set result code format mode
Write command
ATV[<value>]
Response
This parameter setting determines the contents of the header and trailer transmit-
ted with result codes and information responses.
When <value> =0
0
When <value> =1
OK
Parameter
<value>
0 Information response: <text><CR><LF>
Short result code format: <numeric code><CR>
1 Information response: <CR><LF><text><CR><LF>
Long result code format: <CR><LF><verbose code><CR><LF>
Reference
V.25ter
Note
In case of using the command without parameter <value> will be set to 0.
Information responses described in chapter 9 (verbose code and numeric code).
2.31 ATX Set CONNECT result code format and call monitoring
Write command
ATX[<value>]
Response
This parameter setting determines whether or not the TA detects the presence of
dial tone and busy signal and whether or not TA transmits particular result codes.
OK
Parameter
<value>
0 CONNECT result code only returned, dial tone and busy de-
tection are both disabled
1 CONNECT<text> result code only returned, dial tone and busy
detection are both disabled
2 CONNECT<text> result code returned, dial tone detection is
enabled, busy detection is disabled
3 CONNECT<text> result code returned, dial tone detection is
disabled, busy detection is enabled
4 CONNECT<text> result code returned, dial tone and busy de-
tection are both enabled
Reference
V.25ter
Note
Related <text> see chapter 9.1.5.