AT Command Set
MC35_ATC_01_V04.00 Page 172 of 238 02.04.2002
7.2 ^SSTN Remote-SAT Notification
Proactive
Commands
Every time the SIM application issues a proactive command, via the ME, the TA
will receive a notification. This indicates the type of proactive command issued.
AT^SSTGI must then be used by the TA to request the parameters of the proac-
tive command from the ME.
Upon receiving the ^SSTGI response from the ME, the TA must send AT^SSTR
to confirm the execution of the proactive command and provide any required user
response, e.g. selected menu item.
Unsolicited result code
^SSTN: <cmdType>
Parameters
<cmdType> Proactive command ID
Terminate
Proactive
Command
When the SIM application has issued a proactive command, via the ME, to the
TA, it is possible that this command must be terminated. The ^SSTN Unsolicited
Result Code is sent but with a different command type to indicate the termination
of the specified command.
Unsolicited result code
^SSTN: <cmdTerminateValue>
Parameters
<cmdTerminateValue> Terminate proactive command ID
SIM Applica-
tion returns to
main menu
Notification to the TA when the SIM Application has finished a command cycle
and again enters its main menue.
This URC should be used to open this menue on the sreen.
Unsolicited result code
^SSTN: <254>
Reference