19. INSTALLATION DATA
19.1. SITTING OF MACHINE
o In order to get the most out of your machine, we recommend the following sitting:
- A place with a firm floor.
- Environmental temperature of 22º ± 3
- Maximum relative humidity of air 75%
o Avoid the following locations:
- Where machine is exposed to direct sunlight and/or any other heat source.
- Places with nearby vibration sources. If he above location can not be
avoided, provide the machine base with an anti-vibrating system.
- Upper floors. If there is no other alternative, make sure it is placed near a
pillar or reinforce the floor with an extra layer of concrete.
o Provide sufficient free space around the machine to fit accessories, machine
supplements, to carry out repairs, to ensure operator mobility, etc.
19.2. ELECTRICAL DATA
o In order to connect our regulation equipment for energy return to the net, bear in
mind the following requirements:
- This equipment may be connected directly in case the factory network is of
the TN type. This concerns a symmetric three-phase AC network with 4 or 5
wires with the star connection connected to ground (see fig. A).
- With another type of network, use a separator transformer with the star
connection of the secondary connected to ground (see fig. B).
VOLTAGE...................................................................................... 400 V ± 10 %; 50 Hz ± 1 %
SERVICE VOLTAGE .................................................................... 110 V AC / 24 V DC
LAMP ............................................................................................. Protection IP 67; 220 V
ELECTRIC CABINET.................................................................... Protection IP 55
COOLANT OF ELECTRIC CABINET………………………………Protection int. IP 34/ext. IP 54