6
*1 o The measurement program SAMPLIG-DEVICE allows RSC-IOs (on
*1 systems with SPARC architecture only) to be recorded for
*1 disks, TD and openCRYPT-BOX devices (BCAM V18.0, CRYPT V1.2
*1 onwards) and incorporated into the IOs for READ/WRITE ac-
*1 cess.
*1 In the case of disks, the median number of RSC-IOs executed
*1 in parallel is also recorded.
*1 o With the measurement program SERVICETIME, the detailed op-
*1 erating times (function pending, device disconnect and de-
*1 vice connect) have as yet not been recorded by SM2, as the
*1 times could not be delivered by X2000 for the channel con-
*1 nection. Only the device queue time and the remaining ser-
*1 vice time were measured by SM2.
*1 The detailed operating times can be recorded with the fol-
*1 lowing restrictions:
*1 - support for BUS peripheral devices only
*1 (without channel connection verification)
*1 - no measurement of RSC-IOs on TD or openCRYPT-BOX devices
*1 o The measurement program STORAGE-SYSTEM also records meta
*1 volume information for Symmetrix systems. The information
*1 is only given out to the SM2GDAT data interface and is
*1 written in the measurement value file. Provision for the
*1 meta information is supported with INSPECTOR and ANALYZER
*1 only, not for the issuing of SYMMETRIX reports of the TU
*1 part of SM2 or SM2R1.
*1 o The measurement program VM2000 also records data from VM
*1 groups (VM2000 V8.0A onwards).