Installing the
Camera
13
Siemens Building Technologies
Fire Safety & Security Products 03. 2005
7 Installing the Camera
7.1 Installation
1.
Connect the BNC cable to the video output
2.
Connect the power source to the power terminal
Caution:
If using a DC supply, make sure the polarity is correct. Incorrect connection may cause malfunction
and/or damage to the camera.
3. To reduce radiation sufficiently, please wind one turn around the core, see figure
below
Location Core illustration for what camera
Power cable
LP
Y/C cable
LP / MP
EIM-0050751G
4. Adjust the back focus
The back focus is factory-adjusted before delivery for a CS mount lens. If re-
adjustment is necessary, please loosen screw
, set the camera to AES mode
(see section 7.2.14.2: BACK FOCUS), then rotate the back focus wheel until a
sharp image appears. Tighten screw .