8 K44 Duo Technical manual
Wiring
The numbers refer to the diagram on the right.
1
Power in, terminal nos 1(+) and 2. 12-24 V.
2
Input for extra LED (red), terminal nos 3 and
4. 10-35 V DC.
3
Tamper switch, terminal nos 5 and 6. Closed
when the housing is closed.
4
Code disabling from external time clock.
Input 1: Close terminal nos 8 and 7.
Input 2: Close terminal nos 9 and 7.
5
Output for alert or duress. Use E7 relay.
Connect between terminal nos 10 and 1(+).
6
Contact for zero (0) opening. Close terminal
nos 11 and 7.
7
Output for Door bell (buzzer). Use E7 relay.
Connect between terminal nos 12 and 1(+).
8
Input for door contacts. The contact is closed
when the door is closed. Terminal nos 13
and 15 (19 and 21 respectively).
9
Exit button. The door opens on closing
terminal nos 14 and 15 (20 and 21
respectively).
10
Electric locking device. Dashed line refers to
locks with failsafe function.
11
SW1 push button. Used when choosing
password and erasing memory.