Siemens Codelock K44 Duo Manual de servicio Pagina 20

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 32
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 19
20 K44 Duo Technical manual
Door control on/off
If door contacts are used and this function is
activated, a warning signal sounds during the
time set as door held warning time, i.e. when
the opening time has expired and the door is
still open.
If the door held warning time expires and the
door is still open, the alert output is activated
(if the Alert function is activated). This also
happens if the door is forced open.
This is how to activate Door control:
1 Press B and enter the password.
2 Enter A67.
3 Enter 1.
4 Press B to leave programming mode.
To deactivate Door control, press 0 in step 3
instead.