
Detailed descriptions
16.6 Communications processor CP 1616 onboard
SIMATIC IPC627C
178 Operating Instructions, 11/2010, A5E02669068-02
16.5.6 Forcing user consent
Introduction
When establishing a connection to the AMT PC, the KVM viewer may prompt the user to
enter a six-figure code. This code is displayed on the screen of the AMT PC. The user of the
AMT PC must inform the user of the KVM viewer of this code.
Procedure
To set up this code query on the KVM viewer, follow these steps:
1. Select "Intel(R) AMT Configuration > User Consent" in the MEBx.
2. Select the value "KVM" for "User Consent".
To allow a user with administrator privileges to avoid this code query, follow these steps:
1. Select "Intel(R) AMT Configuration > User Consent" in the MEBx.
2. Enable "Opt-in configurable from remote IT".
16.6 Communications processor CP 1616 onboard
16.6.1 Introduction
16.6.1.1 Properties
The CP 1616 onboard allows the connection of industrial PCs to Industrial Ethernet.
The basic characteristics of the PCS 1616 onboard are:
● Optimized for PROFINET IO
● Enhanced Real Time Ethernet Controller 400 = ERTEC 400
● Three RJ45 sockets for connecting terminal devices or addition network components
● Integrated 3-port real-time switch
● Automatic hardware detection
Comentarios a estos manuales