Siemens SIMATIC IPC427C Instrucciones de operaciones Pagina 100

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 182
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 99
Troubleshooting/FAQs
13.2 Problems when using modules of third-party manufacturers
SIMATIC IPC427C
100 Operating Instructions, 10/2010, A5E02414743-03
13.2 Problems when using modules of third-party manufacturers
Problem Possible cause To correct or avoid error
Check your computer configuration:
If the computer configuration corresponds with factory state,
please contact your technical support team.
If the computer configuration has changed, restore the
original factory settings. Remove all third-party modules,
then restart the PC. If the error no longer occurs, the third-
party module was the cause of the fault. Replace this
module with a Siemens module or contact the module
supplier.
The PC crashes
during startup.
I/O addresses are assigned
twice.
Hardware interrupts and/or
DMA channels are assigned
twice
Signal frequencies or signal
levels are not adhered to
Different connector pin
assignments
If the PC still crashes, contact your technical support team.
Vista de pagina 99
1 2 ... 95 96 97 98 99 100 101 102 103 104 105 ... 181 182

Comentarios a estos manuales

Sin comentarios