Siemens SPCK620 Manual de usuario Pagina 43

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 63
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 42
SPCK620/623 Comfort Keypad - User Manual
User menus > INHIBIT
INHIBIT
Zone and alerts from X-BUS devices can be manually inhibited from the keypad. Inhibiting a zone removes that zone from the
system for one alarm set period only.
To inhibit a zones or alerts from X-BUS devices:
Scroll to INHIBIT and press SELECT.1.
Scroll to the desired option in the table below and press SELECT:2.
ZONES
Select the required zone and toggle the setting from NOT INHIBITED to INHIBITED.
XBUS
Isolate the desired alert from EXPANDERS or KEYPADS:
XBUS COMMS LOST
XBUS FUSE FAULT (Expanders only)
X-BUS TAMPER
VIEW INHIBITS
To view a list of the inhibited zones, system alerts and E-BUS devices alerts.
Only the ALARM, EXIT/ENTRY, FIRE EXIT and LINE zone types can be inhibited on the SPC system. All other
zone types are not displayed in the inhibit menus.
If the security grade setting of the SPC system is set to Unrestricted (see page), then the option to inhibit zones
and fault conditions is displayed in the engineer inhibit menus.
© Siemens Industry - 11-19-2009
Vista de pagina 42
1 2 ... 38 39 40 41 42 43 44 45 46 47 48 ... 62 63

Comentarios a estos manuales

Sin comentarios