7.2 Appendix B: User Configuration and Test Options
Tab. 5 User Configuration and Test Options
Operation User Profile
Default
Description
ISOLATE
Manager Isolating a zone deactivates that zone until such time as the zone is de-isolated again.
All zone types on the SPC systems can be isolated.
Use of this feature to deactivate faulty or open zones should be considered carefully;
once a zone is isolated, it is ignored by the system and could be overlooked when setting
the system in the future, compromising the security of the premises.
To isolate a zone, see Section
6.2.
INHIBIT
Standard
Manager
Inhibiting a zone deactivates that zone for one alarm set period. Only alarm, entry/exit,
fire exit and line zone types can be inhibited.
This is the preferred method of deactivating a faulty or open zone as the fault or open
condition is displayed on the Keypad each time the system is being set to remind the
user to attend to that zone.
To inhibit a zone, see Section
6.1.
CHANGE
CODE
Standard
Manager
This menu option allows users to change their user codes.
To change a user code, see Section
6.8.
GRANT
ACCESS
Manager This option allows users to grant access to manufacturer and engineer programming.
To grant engineer access, see Section
6.10. (SPC4000 allows only Engineer Access)
SET DATE
/ TIME
Standard
Manager
Use this menu option to program the time and date on the system.
Ensure the time and date information is accurate; these fields are presented in the event
log when reporting system events.
To set the date and time, see Section
6.3.
TEST
Standard
Manager
This menu option provides the following test features:
1. Bell test: The bell test activates the external bells, strobe, internal bells, and buzzer in
turn for 5 seconds to ensure their correct operation.
2. Walk test: A walk test allows for testing of the operation of all alarm sensors on a
system. When this option is selected, the Keypad displays the number of zones to test
on the system. Activate each alarm sensor (by opening the door or window) and check
for an audible beep at the Keypad. Isolated and inhibited zones are not included in the
walk test.
3. Audible Options: This option allows users to select which devices will activate during
the walk test and which will be silent.
To perform a test, see Section
6.4.
EVENT
LOG
Standard
Manager
This menu option displays the most recent event on the Keypad display. The event log
details the time and date of each logged event.
To view the event log, see Section
6.5.
CHIME
Standard
Manager
All zones that have the CHIME attribute set generate a short burst of audible tone on the
Keypad buzzer when they are opened (while the system is unset).
This menu option allows for enabling or disabling of the chime feature on all zones.
To enable or disable the chime attribute, see Section
6.6.
SETUP
SMS
Manager This feature allows users to set up the SMS messaging service if a modem is installed
on the system.