Siemens SIMATIC NET CP 343-1 Manual de usuario Pagina 39

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 80
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 38
5 Performance Data / Operation
B39
CP 343-1 Advancedfor Industrial Ethernet / Manual Part B
Release 06/2008
C79000-G8976-C202-04
5.6 Characteristic data for E-mail mode
Characteristics
The Advanced CP operates as an E-mail client. It supports the SMTP service
(Simple Mail Transfer Protocol).
To send E-mails, one E-mail connection must always be set up per CP. The E-mail
connection specifies the mail server via which all the mails sent by the Advanced
CP are delivered.
To send E-mail in the user program of the S7 CPU, use the send call of the
SEND/RECEIVE interface (FC AG_SEND / AG_LSEND).
The maximum data length is 8192 bytes.
Authentication
The CP supports the following authentication methods:
S PLAIN
S LOGIN
S CRAMMD5
S DIGESTMD5
5.7 Characteristic data for FTP mode
TCP connections for FTP
FTP actions are transferred from the CP over TCP connections. Depending on the
mode, the following characteristic data apply:
S FTP in client mode:
You can configure a maximum of 10 FTP connections. Up to 2 TCP
connections are occupied per configured FTP connection.
S FTP in server mode:
You can operate a maximum of 2 FTP sessions at the same time. Up to 2 TCP
connections are occupied per FTP session (1 control connection and 1 data
connection).
Vista de pagina 38
1 2 ... 34 35 36 37 38 39 40 41 42 43 44 ... 79 80

Comentarios a estos manuales

Sin comentarios