2 Requirements for Use
B−13
CP 343-1 Advancedfor Industrial Ethernet / Manual Part B
Release 06/2008
C79000-G8976-C202-04
2.2 Configuration
Downloading configuration data
It is possible to download the configuration data to the CP via MPI or
LAN/Industrial Ethernet. Addressing for the first time is possible only over the
PROFINET interface of the CP. The following version of STEP 7 is required:
Table 2-4
STEP 7 version
Functions of the CP
V5.4 Service Pack 4 Requirement for configuring all functions of the CP.
Project engineering for PROFINET CBA
To be able to work in the PROFINET CBA environment, you require the SIMATIC
iMap engineering tool.
SIMATIC iMap requires a connection over Industrial Ethernet (TCP/IP protocol).
The following SIMATIC iMap project engineering software is required:
Table 2-5
SIMATIC iMap version
Functions of the CP
as of V3.0 + Service Pack 1 The full PROFINET CBA functionality of the device can be used as
of hardware version 1 and firmware version V1.0.
Table 2-6
Version STEP 7 add-on
Functions of the CP
as of V3.0 + Service Pack 4 The full functionality as described in this document can be used.
To operate PROFINET CBA, you require the current service packs of SIMATIC
iMap containing the current FB88 V1.5 function block:
SIMATIC iMap V3.0 − Download Service Pack 1
SIMATIC iMap STEP 7 add-on V3.0 − Download Service Pack 4
http://support.automation.siemens.com/WW/view/de/10805413