Chapter 3
Device Management
RUGGEDCOM ROS
User Guide
68 Deleting an RMON Alarm
Parameter Description
The index of the event that is used when a rising threshold is crossed. If there is no
corresponding entryl in the Event Table, then no association exists. In particular, if this
value is zero, no associated event will be generated.
Owner Synopsis: Any 127 characters
Default: Monitor
The owner of this record. It is suggested to start this string withword 'monitor'.
4. Click Apply.
Section 3.9.2.3
Deleting an RMON Alarm
To delete an RMON alarm, do the following:
1. Navigate to Ethernet Stats » Configure RMON Alarms. The RMON Alarms table appears.
Figure 35: RMON Alarms Table
2. Select the alarm from the table. The RMON Alarms form appears.