2000585-001 Data Communications Setup 61
Firmware Updates, Continued
6. Click on Send Text File.
The Send Text File dialog box will appear. In the Look in: window
choose the directory on your PC where the DNH files reside. Typi-
cally this would be aai.
7. Under Files of type select All files (*.*).
8. Under File name type in the upgrade version file name (DataNET
hub.hex).
This will start the down loading of the files. Once the download has
begun the block numbers will be displayed as they are transmitted.
The upload will take approximately 45 minutes to complete.
9. Repeat steps 1 through 8 for Hub ‘B’ half.
To configure the Ethernet MAC address after the firmware upade per-
form the following steps:
1. At the Local > prompt type: config address etherenet
xx.xx.xx.xx.xx.xx
where: xx.xx.xx.xx.xx.xx is the MAX address for the DataNET Hub
board. Typically the address would be in the range 00.c0.c9.01.21.00
through 00.c0.c9.01.21.ff.
2. Press Enter to complete your entry.
MAC Address Con-
figuration