Module E11
Status: 01/2010 Radio Frequency Identification (RFID) with SIMATIC S7-300F-2PN/DP and
RF180C
Variable Description
multitag MOBY U/D or RF300; maximum number of MDS processed in parallel in the field. Permissible
values: 1
MOBY U: BERO operating mode; aerial field is switched on/off automatically. The command
"Aerial ON/OFF“ is overlaid by the BERO operating mode.
00 hex = Without BEROs; no reader synchronization
01 hex = One or two BEROs;
The BEROs are logically ored. While a BERO is operated, the field is
switched on
02 hex = One or two BEROs.
The 1st BERO switches the field on and the 2nd BERO switches the
field off. If there are 2 BEROs and one field_ON_time is parameterized,
the field is switched off automatically if the 2nd BERO does not switch
within the BERO time.
If no field_ON_time is parameterized, the field remains switched on until
the 2nd BERO is operated.
03 hex = Activate reader synchronization by means of cable connection (refer to
manual for Configuration, Installation and Service for MOBY U)
field_ON_control
MOBY D or RF300: 00 hex (reserved)
MOBY U: time for BERO operating mode (field_ON_control = 02)
00 hex = Time monitoring is switched off. For field switch-off, the 2nd BERO is
needed.
01 hex .. FF hex = 1...255s switch-on time for the Reader field
MOBY D: MDS type
00 hex = I-code 1 (for example, MDS D139)
01 hex = ISO MDS
field_ON_time
RF300: 00 hex (reserved)
reserved Reserved
Notes
Parameter “field_ON_time value = 0 for MDS type RF300 ___________________________
Parameter “field_ON_time“ value = 1 for MDS type ISO______________________________
__________________________________________________________________________
__________________________________________________________________________
__________________________________________________________________________
__________________________________________________________________________
__________________________________________________________________________
__________________________________________________________________________
__________________________________________________________________________
Vista de pagina 44
1 2 ... 40 41 42 43 44 45 46 47 48 49 50 ... 64 65

Comentarios a estos manuales

Sin comentarios