Connecting CU230P-2 DP to the PROFIBUS DP network
Commissioning of the Control Unit CU230P-2 DP with PROFIBUS ID-No: 35934076
Version 1 Issue May 2009 8/33
Copyright © Siemens AG 2009 All rights reserved
PDF_Commissioning_of_CU230P_2_DP_with Profibus_en_V1.doc
2 Connecting CU230P-2 DP to the PROFIBUS DP
network
2.1 Integrating an inverter into the PROFIBUS DP fieldbus system
To integrate the inverter into the PROFIBUS DP fieldbus system, a 9-pin
sub-D connector conforming to the PROFIBUS standard can be found on
the underside of the CU230P-2 DP control unit. The terminals in this
connector are short-circuit proof and potential-free.
Figure 2-1 Sub-D connector on the CU230P-2 DP
You will find the pin assignments in the following table:
Table 2-1 Pin assignments for the 9-pin sub D connector (socket)
Contact Designation Description
1 PE/shield Ground connection
2 --- ---
3 DPB Data P receive/transmit (B/B’)
4 RTS Control signal
5 0V
Reference potential for PROFIBUS data
(C/C’)
6 5V Supply voltage plus
7 --- ---
8 DPA Data N receive/transmit (A/A’)
9 --- ---
Enclosure PE/shield Cable shield