7ML19985JM01 SITRANS LR 460 – INSTRUCTION MANUAL Page 15
mmmmm
Installation
Easy Aimer Installation
1. Holding the electronics enclosure firmly,
loosen the Easy Aimer ball locking bolts and
gently reposition the enclosure.
2. Direct SITRANS LR 460 so the horn antenna is
pointed at an angle perpendicular to the
material surface, if possible. (As a guide, aim
the beam at a point approximately 2/3 of the
way across the tank diameter.)
3. When the desired position is reached, re-
tighten the 5 bolts to 15-23 N m (11 to 17 Lbf-ft).
Note: When the Easy Aimer ball is loosened, the device is free to tilt to a maximum of
30°.
top clamping plate (upper socket)
bottom clamping plate
(lower socket)
customer gasket as
required [recommended
thickness 1.5 to 1.8 mm (0.06
to 0.07")]
customer mounting plate,
as required
ø 4" (102 mm) min.,
central opening
30°
max.
285 mm
(11.22")
0.38"
(10 mm)
Easy Aimer ball locking bolts
S
I
TRA
N
SLR4
0
0
Easy Aimer