PROFIBUS DP Master Interface IM 467/IM 467 FO
8-7
S7-400, M7-400 Programmable Controllers Module Specifications
A5E00069467-07
Prerequisites
The IM 467/IM 467 FO is supported by all the CPU operating systems beginning
with the release numbers listed below.
You will also find the following information in the table:
The number of IM 467/IM 467 FO that can be operated on a CPU
Support of multiprocessor operation
Table 8-2 CPU and IM 467/467 FO
CPU
MLFB Number Release Multiprocessor
Operation
Possible
No. of IM
467
Possible
412 6ES7412-1XF03-0AB0 1 Yes 4
412-2 6ES7412-2XG00-0AB0 1 Yes 4
414-2 6ES7414-2XG03-0AB0 1 Yes 4
416-2 6ES7416-2XK02-0AB0 1 Yes 4
416-3 6ES7414-3XL00-0AB0 1 Yes 4
417-4 6ES7417-4XL00-0AB0 1 Yes 4