00497GB-2009/R01
Availability, design and specifi cations are subject to change without notice. All rights reserved.
X024 - 33
www.asconumatics.eu
ISO 5599/2 Size 1 2 3
I24 BA 4 15 M Q 000 61
Series and Port Size
I12* =
ISO 5599/2 Size 1 = 1/4
I13 =
ISO 5599/2 Size 1 = 3/8
I23* =
ISO 5599/2 Size 2 = 3/8
I24 =
ISO 5599/2 Size 2 = 1/2
I34* =
ISO 5599/2 Size 3 = 1/2
I35 =
ISO 5599/2 Size 3 = 3/4
* Use for valve unit only
First letter = "14" Actuator
Second letter = "12" Actuator
BA =
Single solenoid pilot actuated valve
with spring control
BB =
Double solenoid pilot actuated valve
locking
BW =
Single solenoid pilot actuated valve
with differential air return
(ISO 2 + ISO 3 series only)
SA =
Single direct solenoid actuated valve
with spring return
SS =
Double direct solenoid actuated valve
locking
00 =
Valve without manifold block
Function
4 =
5-ported, 2-pos. valve
5 =
5-ported, 3-pos. valve,
1 blocked, 2 & 4 exhausted
6 =
5-ported, 3-pos. valve,
all ports blocked
7 =
5-ported, 3-pos. valve,
1 connected with 4 & 2
P =
Blank station plate
Mounting
00 =
Valve unit only
01 =
00 with speed control
15* =
Manifold block with side and bottom
ports
25 =
15 with speed control
3*A =
Manifold block with side ports and
individual exhaust
3B =
Manifold block with side and bottom
ports and individual exhaust
3C =
3A with speed control
3D =
3B with speed control
MN =
Midstation supply and exhaust block
without "Z-Board"™
MS =
Midstation supply and exhaust block
with "Z-Board"™
Z1 =
Manifold block with side and bottom
ports, single "Z-Board"™
Z2* =
Manifold block with side and bottom
ports, double "Z-Board"™
Z5 =
Z1 with speed control
Z6 =
Z2 with speed control
*also used with function P = blank station
** not available for ISO 5599/2 Size 1
Voltage
00 =
Blank station plate
61 =
24 VDC*
* cannot be used with direct solenoid actuated
Valves of ISO 3 Series
Options
000 =
Standard
11B =
Flush manual override
11Z =
Extended locking manual override
14B =
Internal pilot supply from port 1
if not standard
14C* =
Internal pilot supply from port 3
14D* =
Internal pilot supply from port 5
15G =
5 pin mini connector (valve conduit cover)
14X* =
External pilot supply through base or
manifold end plates
* must use one of these options when used with RC, RQ or
RD regulators and solenoid pilot valves.
Port Type
G =
G-thread
(direct solenoid valves)
Q =
G-thread
(solenoid pilot valves)
Wiring Option
M =
Plug-in VDC with LED indicator
O =
Blank station plate
Note:
Internal pilot supply from port 1 is standard for all ISO 5599/2 valve series.