INSTALLATION
2-17
2.5.8 ERROR COUNT: Error count statistics
Errors count objects:
This group provides administrator a reference to detected transmission
error counts. This error-count objects will count the statistic error during
one second, and is restarted every second. Table 2-7 lists all objects.
CRC4 Error Count: Counter that counts detected CRC4 errors. This
counter will restart at every second and will stop counting during E1
SYNC LOSS.
E Bit Count: Counter that reports the received E Bits from remote
equipment. This counter will restart at every second and will stop
counting during E1 SYNC LOSS.
FAS Error Count: Counter that counts Frame Alignment Signal error
words. This counter will restart at every second.
Object name Description Len.
CRC4 Error Count
Detected CRC4 errors per second. 10
E Bit Count
Received E Bit count per second. 10
FAS Error Count
Detected FAS error counts per second on received frames. 12
Len. : Size of counter in bits.
Table 2-7 ERROR Count Object list