INSTALLATION
2-10
2.5.4 DACS SET: Time slot interchange map
This group contains all time slot interchange mapping information of all
E1s and TDM bus on the same ETx. Each entry of this map contains
following four items:
Available objects:
Source time slot Target time slot State Command
‘Source time slot’ is expressed as:
EPn:xx, where n is the E1 port number, xx is the time-slot number of
E1. Or TDn:xx, where n is the TDM bus number, xx is the time-slot
number of TDM bus.
‘Target time slot’ is expressed as:
EPn:xx, where n is the E1 port number, xx is the time-slot number of
E1. Or TDn:xx, where n is the TDM bus number, xx is the time-slot
number of TDM bus
‘State’ is expressed as:
D*/ß Disconnect (disabled entry/disconnect target and source)
C*/ß Connect (effective entry/connect target and source)
‘Command’ is the action to execute current setting. Valid commands are:
* Do not apply the change (pressing [ENTER] with this symbol will not
apply any change of the entry)
ß Apply this entry (this symbol will show only during front panel
operation. After the entry is applied, this symbol
will return to ‘*’ as normal state)
Example:
Cross-connecting between time slot 05 of the 1
st
E1 and time slot 13 of
the 2
nd
E1:
EP1:05 EP2:13 Cß
Disable an entry:
EP2:30 TD2:15 Dß
Cross-connecting between time slot 10 of the 1st E1 and time slot 25 of
TDM bus 6:
EP1:10 TD6:25 Cß
*Note:
If the assigned time slot in a new entry is occupied by other entries, the controller
will notice operator by displaying ‘Error Setting’, and no changes will be applied.