Siemens EF 79 Series Manual de usuario Pagina 23

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 30
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 22
20.03.2015 BJJ
Unrestricted © Siemens AG 2015 All rights reserved.
Page 27 Author / Department
Output components
Sine-wave filter
A sine-wave filter limits the voltage gradient and the
capacitive re-charging currents that generally occur at
the motor terminals for inverter operation.
The sine-wave filter at the inverter output supplies almost
sinusoidal voltage at the motor. As a consequence,
standard motors without special cable can be used.
Operation permissible at pulse frequencies of 4 kHz
up to 8 kHz (sine-wave filter from 160 kW and higher,
only for 4 kHz)
A power reduction (derating) of 5 % must be taken
into consideration when selecting a suitable inverter
The output frequency is limited to 150 Hz
Sine-wave filters can be used with the following Power
Modules
PM230 FS D-F
PM240 FS D-GX
PM250