Simatic/TI 505 Ethernet Driver Help
P 15/16, 0/1 Not used, set to 0
*Elements A and B are write-only triggers. Writing 1 to the triggers sets the mode. The mode (or status) is
reported in Element L (Bit 12).
**If a word is selected for the analog alarm V-flags, element L is written as bit 12 is written. If a C or Y is
selected, bit 12 (element L) is not used.
Note: If an analog alarm is programmed and not disabled, the controller will begin to monitor the programmed
variables as soon as the controller is placed in RUN mode.
ACF Bit Definitions
Analog Alarm Control Flag Data Element Format
The server default settings are shown in bold.
MSB LSB
ABCD EFGH IJKL MNOP QRST UVWX YZab cdef
The ACF bit has the following format:
V/W, X/Y
V=0-based bit addressing. Bit 0 is MSB.
W=1-based bit addressing. Bit 1 is MSB (Simatic 505 documentation).
X=0-based bit addressing. Bit 0 is LSB.
Y=1-based bit addressing. Bit 1 is LSB.
Element ACF bit Description
A 0/1, 31/32 0=PV scale 0% offset
1=PV scale 20% offset
B 1/2, 30/31 1=Take square root of PV
C 2/3, 29/30 1=Monitor HIGH/LOW alarms
D 3/4, 28/29 1=Monitor HIGH-HIGH/LOW-LOW alarms
E 4/5, 27/28 1=Monitor yellow/orange deviation alarm
F 5/6, 26/27 1=Monitor rate-of-change alarm
G 6/7, 25/26 1=Monitor broken transmitter alarm
H 7/8, 24/25 0=Local setpoint
1=Remote setpoint
I 8/9, 23/24 Unused, set to 0
J 9/10, 22/23 Unused, set to 0
K 10/11, 21/22 Unused, set to 0
L 11/12, 20/21 Unused, set to 0
M 12/13, 19/20 Unused, set to 0
N 13/14, 18/19 Unused, set to 0
O 14/15, 17/18 Unused, set to 0
P 15/16, 16/17 Unused, set to 0
Q 16/17, 15/16 Unused, set to 0
R 17/18, 14/15 Unused, set to 0
S 18/19, 13/14 Unused, set to 0
T 19/20, 12/13 Unused, set to 0
U 20/21, 11/12 0=Process variable is unipolar
1=Process variable is bipolar
V 21/22, 10/11 Unused, set to 0
W 22/23, 9/10 Contains SF program number (if an SF program is scheduled to be called)
X 23/24, 8/9 Contains SF program number (if an SF program is scheduled to be called)
Y 24/25, 7/8 Contains SF program number (if an SF program is scheduled to be called)
Z 25/26, 6/7 Contains SF program number (if an SF program is scheduled to be called)
a 26/27, 5/6 Contains SF program number (if an SF program is scheduled to be called)
b 27/28, 4/5 Contains SF program number (if an SF program is scheduled to be called)
c 28/29, 3/4 Contains SF program number (if an SF program is scheduled to be called)
d 29/30, 2/3 Contains SF program number (if an SF program is scheduled to be called)
www. kepware.com