Pagina 1 - Ethernet Driver Help

Simatic / TI 505Ethernet Driver Help© 2015 Kepware Technologies

Pagina 2 - Table of Contents

Simatic/TI 505 Ethernet Driver HelpEach device has now been defined under its own channel. Inthis new configuration, a single path of execution isdedi

Pagina 3 - Overview

Simatic/TI 505 Ethernet Driver HelpData Types DescriptionData Type DescriptionBoolean Single bitWord Unsigned 16-bit valuebit 0 is the low bitbit 15 i

Pagina 4 - Device Setup

Simatic/TI 505 Ethernet Driver HelpAddress DescriptionsAddress specifications vary depending on the model in use. Select a link from the following lis

Pagina 5 - Communications Parameters

Simatic/TI 505 Ethernet Driver HelpV-Word MemoryBCD DecimalV<address>B 1-167772151-16777214Short, Word,BCDLong, DWord,FloatRead/WriteV-Word Memo

Pagina 6 - CAMP vs. Packed Task Code

Simatic/TI 505 Ethernet Driver HelpDWord, FloatSystem StatusBit AccessSTW<address>.<bit>STW<address>:<bit>STW<address>,&

Pagina 7 - Addressing Options

Simatic/TI 505 Ethernet Driver HelpThis type of string is a Standard String with LoHi byte order except the string length is always the maximumbecause

Pagina 8

Simatic/TI 505 Ethernet Driver HelpNote: All 10 characters are displayed with the null-terminated string "hello" padded with 5 spaces to fil

Pagina 9

Simatic/TI 505 Ethernet Driver Help0 = Status is good.1 = Base is not present or has a problem.Bit 1, Base 15Bit 2, Base 14Bit 3, Base 13Bit 4, Base 1

Pagina 10

Simatic/TI 505 Ethernet Driver HelpBit 9-12, Seconds - Tens digitBit 13-16, Seconds - Units digitSTW144 Bit 1-4, Seconds - Tenths digitBit 5-8, Second

Pagina 11 - Data Types Description

Simatic/TI 505 Ethernet Driver Help1 = Error or single power supplySTW00177-00183 Not used x x x xSTW00184 Module Mismatch IndicatorBit 1, 1 = Module

Pagina 12 - Common Data Type Addressing

Simatic/TI 505 Ethernet Driver HelpTable of ContentsTable of Contents 2Simatic / TI 505 Ethernet Driver Help 3Overview 3Device Setup 4Cable Diagrams 5

Pagina 13

Simatic/TI 505 Ethernet Driver HelpSTW213 Bit 1-16 slave addresses 48-33STW214 Bit 1-16 slave addresses 64-49STW215 Bit 1-16 slave addresses 80-65STW2

Pagina 14 - String Support

Simatic/TI 505 Ethernet Driver HelpChecksumSTW00243 Reserved N/A N/A N/A xSTW00244 Additional Control Status FlagsBit 1, Controller Mode 0 = Program M

Pagina 15

Simatic/TI 505 Ethernet Driver HelpNote: The actual number of addresses available for of each type depends on the PLC's configuration. If the dri

Pagina 16 - Status Words

Simatic/TI 505 Ethernet Driver HelpAlarm MSW AlarmC FlagsACFH<address> 1-65536 Word Read/WriteAlarm LSW AlarmC FlagsACFL<address> 1-65536

Pagina 17

Simatic/TI 505 Ethernet Driver HelpP 15/16, 0/1 Not used, set to 0*Elements A and B are write-only triggers. Writing 1 to the triggers sets the mode.

Pagina 18

Simatic/TI 505 Ethernet Driver Helpe 30/31, 1/2 Contains SF program number (if an SF program is scheduled to be called)f 31/32, 0/1 Contains SF progra

Pagina 19

Simatic/TI 505 Ethernet Driver HelpLoop Raw Setpoint LSPR<address> 1-65536 Word Read/WriteLoop Raw Error LERRR<address> 1-65536 Word Read

Pagina 20

Simatic/TI 505 Ethernet Driver HelpElement LVF bit DescriptionA 0/1, 15/16 1=Go to manual mode*B 1/2, 14/15 1=Go to auto mode*C 2/3, 13/14 1=Go to cas

Pagina 21 - Alarm Addressing

Simatic/TI 505 Ethernet Driver HelpL 11/12,20/211=Auto-mode lockM 12/13,19/201=Cascade-mode lockN 13/14,18/191=Setpoint lockO 14/15,17/180=Output scal

Pagina 22

Simatic/TI 505 Ethernet Driver Help12/13E 4/5,11/121=Wait. This bit is set during a soak period when the PV is not within a specifieddeviation from th

Pagina 23 - AVF Bit Definitions

Simatic/TI 505 Ethernet Driver HelpSimatic / TI 505 Ethernet Driver HelpHelp version 1.037CONTENTSOverviewWhat is the Simatic / TI 505 Ethernet Driver

Pagina 24 - ACF Bit Definitions

Simatic/TI 505 Ethernet Driver Helpenough addresses are found to fill the output buffer. The search will cycle through all address types (C then X/Yfo

Pagina 25 - Loop Addressing

Simatic/TI 505 Ethernet Driver HelpError DescriptionsThe following messages may be generated. Click on the link for a description of the message.Addre

Pagina 26 - LVF Bit Definitions

Simatic/TI 505 Ethernet Driver HelpData type <type> is not valid for device address <address>.Error Type:WarningPossible Cause:A tag addre

Pagina 27 - LCF Bit Definitions

Simatic/TI 505 Ethernet Driver HelpSolution:Check network connections.Device <device name> detected a Task Code error <error> (tag <add

Pagina 28 - LRSF Bit Definitions

Simatic/TI 505 Ethernet Driver HelpPossible Cause:The device is unable to receive the amount of write data sent in one request.Note:This error is used

Pagina 29 - Find Forced Addressing

Simatic/TI 505 Ethernet Driver HelpPossible Cause:The version number of the Winsock DLL found on the system is less than 1.1.Solution:Upgrade Winsock

Pagina 30 - Output Formats

Simatic/TI 505 Ethernet Driver HelpTask Code Error CodesCode Description02 Address out of range (other than ladder logic).03 Requested data not found.

Pagina 31

Simatic/TI 505 Ethernet Driver HelpIndex5505 Protocol 6AACF Bit Definitions 24Address <address> is out of range for the specified device or regi

Pagina 32

Simatic/TI 505 Ethernet Driver HelpFFind Forced Addressing 29Float 11LLCF Bit Definitions 27Long 11Loop Addressing 25LRSF Bit Definitions 28LVF Bit De

Pagina 33

Simatic/TI 505 Ethernet Driver HelpWWinsock initialization failed (OS Error = n). 34Winsock V1.1 or higher must be installed to use the Simatic/TI 505

Pagina 34

Simatic/TI 505 Ethernet Driver HelpDevice SetupSupported DevicesCTI Interface CardsCTI 2572, CTI 2572-A, and CP2572 Ethernet interface cards on TI ser

Pagina 35 - Solution:

Simatic/TI 505 Ethernet Driver HelpCable DiagramsCommunications Parameterswww. kepware.com5

Pagina 36 - Task Code Error Codes

Simatic/TI 505 Ethernet Driver HelpDescriptions of the parameters are as follows:l Port Number: This parameter specifies the port number that the remo

Pagina 37

Simatic/TI 505 Ethernet Driver HelpFor applications where the data can be divided into large blocks, using CAMP memory transfer will result in themost

Pagina 38

Simatic/TI 505 Ethernet Driver HelpBit Order for V, K, WX, WY and STWThis option is used to select the order in which bits will be presented to V, K,

Pagina 39

Simatic/TI 505 Ethernet Driver HelpOptimizing Simatic / TI 505 Ethernet CommunicationsThe Simatic / TI 505 Ethernet driver has been designed to provid