16 SPARC Enterprise M8000/M9000 Servers Product Notes for XCP Version 1072 September 2008
6508432 Many correctable errors (CE) may occur, and
despite these are the correctable errors,
domain may panic.
This bug has been fixed in Solaris 10 8/07.
For Solaris 10 11/06, this has been fixed in
patch 120011-08.
[Workaround]
Set the following to /etc/system and then
reboot the domain:
set pcie:pcie_aer_ce_mask = 0x2001
6508434 The domain may panic when an additional
PCI-X card is installed or a PCI-X card is
replaced by using PCI hot plug.
This bug has been fixed in Solaris 10 8/07.
For Solaris 10 11/06, this has been fixed in
patch 120011-08.
[Workaround]
Do not insert a different type of PCI-X card on
the same PCI slot by using PCI hot plug.
6509337 s10s_u3 wanboot fails - The server returned
416: Requested Range Not Satisfiable.
This bug has been fixed in Solaris 10 8/07.
6510861 When Dual-Channel Ultra320 SCSI Card
(SE0X7SC2F, SE0X7SC2X) is mounted,
correctable errors(CE) occur and system may
panic.
This bug has been fixed in Solaris 10 8/07.
For Solaris 10 11/06, this has been fixed in
patch 120011-08.
[Workaround]
Add the following entry to the /etc/system
file and then reboot the system:
set pcie:pcie_aer_ce_mask = 0x31c1
6511374 Unexpected error messages may be displayed
on console after changing the system
configuration.
Example:
WARNING: Translation error source
/LSB0/B0/0, PA 3c000000000, target
/LSB0/B0/20000000
This message can be safely ignored.