Multiplexer User's Guide
Confidential / Released
s
mo b i l e
Mux_guide_v06 Page 23 of 36 30.06.2004
Customer
µC
GSM engine
µC
Closed Down Closed Down
RequestStartUp
ResponseStartUp
ConfirmStartUp
IndicationStartUp
DisconnectedDisconnected
Serial
interface
Start Up
"AT+CMUX"
Connected
RequestSABM
IndicationSABM
ResponseDM
ConfirmDM
DLC Establishment,
DLC created
DisconnectedDisconnected
RequestSABM
IndicationSABM
ResponseUA
ConfirmUA
DLC Establishment,
DLC not created
ConnectedConnected
ConnectedConnected
RequestUIH
IndicationUIH
IndicationUIH
RequestUIH
Connected
Information
Transfer
Figure 5: MPI – Startup, DLC establishment and information transfer